The AIG-101 Series gateways are entry-level IIoT gateways that connect Modbus RTU/ASCII/TCP devices to cloud platforms and applications such as Azure, AWS, and MQTT. The AIG-101 as a Modbus master can integrate existing Modbus devices with cloud platforms, effortlessly collecting and transmitting data to the Azure and AWS clouds. Moreover, the gateways also support the Modbus TCP slave mode, enabling simultaneous transmission of data to a cloud platform and local SCADA system.
As the number of field sites increases, additional I/O or serial interfaces are required to connect devices, such as sensors, meters, and inverters, for collecting and processing the large amount of data that is generated. A typical approach is to install remote I/O and device servers to extend the interfaces, but the configuration settings required can be a nightmare for most users. To provide an extremely simple configuration process for interface extension, AIG-101 gateways have better integration and come with an intuitive wizard that can configure Moxa ioLogiks and UPorts with just a few clicks.
Energy Management Systems mainly collect energy data such as average power generation and energy efficiency. This data is then used to display on-site conditions, observe the energy trend, and optimize energy usage. Most edge systems require additional programming to process the data required by energy management system. The AIG-101 can preprocess the edge data and directly send meaningful data to the energy management systems. The intuitive UI enables easy configuration of the IIoT gateway settings to collect and process data.
The AIG-101 comes with powerful troubleshooting tools to diagnose issues with protocol statuses and capture and analyze traffic packets, enabling engineers to remotely identify the root cause of issues and quickly bring the operation back to normal. The tools also provide secure remote access to the AIG-101 to enable the maintenance engineers to directly access it, saving a lot of time and effort and reducing system downtime in energy management systems.
AIG-101-T-AP/EU/US
AIG-101-T
Save
2, Auto MDI/MDI-X connection
1.5 kV (built-in)
Modbus TCP Client (Master) / Server (Slave) Generic MQTT Azure IoT Device AWS IoT Core
Web Console (HTTP/HTTPS)
NTP Client GPS
2
DB9 male
RS-232/422/485
300 bps to 921.6 kbps
7, 8
None, Even, Odd, Space, Mark
1, 2
RTS/CTS
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Tx+, Tx-, Rx+, Rx-, GND
Data+, Data-, GND
LTE Cat. 1
SMA x 2
Nano SIM
SMA x 1
US Model:LTE Bands: Band 2 (1900 MHz) / Band 4 (1700 MHz) / Band 5 (850 MHz) / Band 12 (700 MHz) / Band 13 (700 MHz) / Band 14 (700 MHz) / Band 66 (1700 MHz) / Band 71 (600 MHz)UMTS Bands: 2 (1900 MHz) / Band 4 (1700 MHz) / Band 5 (850 MHz)Carrier Approval: Verizon, AT&TEU Model:LTE Bands: Band 1 (2100 MHz) / Band 3 (1800 MHz) / Band 7 (2600 MHz) / Band 8 (900 MHz) / Band 20 (800 MHz) / Band 28 (700 MHz)UMTS Bands: Band 1 (2100 MHz) / Band 3 (1800 MHz) Band 8 (900 MHz)AP Model:LTE Bands: Band 1 (2100 MHz) / Band 3 (1800 MHz) / Band 5 (850 MHz) / Band 8 (900 MHz) / Band 28 (700 MHz)UMTS Bands: Band 1 (2100 MHz) / Band 5 (850 MHz) / Band 8 (900 MHz)
Modbus RTU/ASCII Master
Master
1, 2, 3, 4, 5, 6, 15, 16, 23
256 per port
Server (Slave) Client (Master)
4
64
1500
v3.1.1 v3.1
0, 1, 2
Username and password
TLS 1.0 TLS 1.1 TLS 1.2
Keep Alive Retain Message Clean Session Will and Testament
Store and Forward Custom Payload Remote API Invocation
MQTT MQTT over WebSockets AMQP AMQP over WebSockets
Symmetric Key X.509 Certificate
Reboot Software Upgrade Remote API Invocation
Store and Forward Custom Payload
0,1
X.509 Certificate Private Key Trusted Root CA
Keep Alive
Up to 32 GB (SD 2.0 compatible) Max. No. of Tags Supported: 1500
9 to 36 VDC
Screw-fastened Euroblock terminal
8 W (max.)
128.5 x 89.1 x 41 mm (5.06 x 3.51 x 1.61 in)
Metal
DIN-rail mounting Wall mounting (with optional kit)
AIG-101-T: 492 g (1.08 lb)AIG-101-T-AP/EU/US: 512 g (1.13 lb)
5 to 95% (non-condensing)
-40 to 70°C (-40 to 158°F)
-40 to 85°C (-40 to 185°F)
EN 55032/35
CISPR 32, FCC Part 15B Class A
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
IEC 62368-1 UL 62368-1 EN 62368-1
IEC 60068-2-27
IEC 60068-2-64 5 Grms @ 5 to 500 Hz, random wave, 1 hr per axis (without USB devices attached)
EN 303 413 (GPS) EN 301 908-1 (WCDMA/LTE) EN 301 908-2/-13 (WCDMA/LTE) EN 301 489-1/-19 EN 301 489-1/-52 EN 62311
FCC PTCRB RCM
Verizon AT&T
RoHS, CRoHS, WEEE
566,458 hrs
Telcordia SR332
5 years
See www.moxa.com/warranty
File Name: Firmware for Nport 6000 Series
Version: xx
SHA-512 Checksum: --checksum placeholder--
Copied to clipboard
This site uses cookies in order to improve your user experience and to provide content tailored specifically to your interests. By continuing to browse our site without changing your cookie settings (click the Learn More button for more information), or by clicking the OK button below, you hereby acknowledge and agree to our Privacy Policy and use of cookies.
You are currently on the Global / English site. Would you like to go to the site for your region?