As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.

EDS-2010-ML Series

8+2G-port Gigabit unmanaged Ethernet switches

moxa-eds-2010-ml-series-image-(1).jpg | Moxa
moxa-eds-2010-ml-series-image-1-(1).jpg | Moxa
moxa-eds-2010-ml-series-image-2-(1).jpg | Moxa

Features and Benefits

  • 2 Gigabit uplinks with flexible interface design for high-bandwidth data aggregation
  • QoS supported to process critical data in heavy traffic
  • Relay output warning for power failure and port break alarm
  • IP30-rated metal housing
  • Redundant dual 12/24/48 VDC power inputs
  • -40 to 75°C wide operating temperature range (-T models)

Certifications

  • moxa-dnv-certification-logo-image.png | Moxa
  • moxa-iecex-certification-logo-image.png | Moxa
  • moxa-ce-certification-logo-image.png | Moxa
  • moxa-fcc-certification-logo-image.png | Moxa
 
Contact Sales

Introduction

The EDS-2010-ML series of industrial Ethernet switches have eight 10/100M copper ports and two 10/100/1000BaseT(X) or 100/1000BaseSFP combo ports, which are ideal for applications that require high-bandwidth data convergence. Moreover, to provide greater versatility for use with applications from different industries, the EDS-2010-ML Series also allows users to enable or disable the Quality of Service (QoS) function, broadcast storm protection, and the port break alarm function with DIP switches on the outer panel.

The EDS-2010-ML Series has 12/24/48 VDC redundant power inputs, DIN-rail mounting, and high-level EMI/EMC capability. In addition to its compact size, the EDS-2010-ML Series has passed a 100% burn-in test to ensure it will function reliably in the field. The EDS-2010-ML Series has a standard operating temperature range of -10 to 60°C with wide-temperature (-40 to 75°C) models also available.

  • 10/100BaseT(X) Ports (RJ45 connector)

    8
    Auto negotiation speed
    Full/Half duplex mode
    Auto MDI/MDI-X connection

  • Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)

    2
    Auto negotiation speed
    Auto MDI/MDI-X connection
    Full/Half duplex mode

  • Standards

    IEEE 802.3 for 10BaseT
    IEEE 802.3u for 100BaseT(X)
    IEEE 802.3ab for 1000BaseT(X)
    IEEE 802.3z for 1000BaseX
    IEEE 802.3x for flow control
    IEEE 802.1p for Class of Service

  • Ethernet Interface

    Quality of Service (QoS)
    Broadcast storm protection
    Port break alarm

  • Alarm Contact Channels

    Relay output with current carrying capacity of 1 A @ 24 VDC

  • MAC Table Size

    8 K

  • Packet Buffer Size

    4 Mbits

  • Processing Type

    Store and Forward

  • Connection

    1 removable 6-contact terminal block(s)

  • Input Current

    0.251 A @ 24 VDC

  • Input Voltage

    12/24/48 VDC
    Redundant dual inputs

  • Operating Voltage

    9.6 to 60 VDC

  • Overload Current Protection

    Supported

  • Reverse Polarity Protection

    Supported

  • Housing

    Metal

  • IP Rating

    IP30

  • Dimensions

    36 x 135 x 95 mm (1.41 x 5.31 x 3.74 in)

  • Weight

    498 g (1.10 lb)

  • Installation

    DIN-rail mounting
    Wall mounting (with optional kit)

  • Operating Temperature

    EDS-2010-ML-2GTXSFP: -10 to 60°C (14 to 140°F)
    EDS-2010-ML-2GTXSFP-T: -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

  • Safety

    UL 61010-2-201
    EN 62368-1(LVD)

  • EMC

    EN 55032/35
    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 MHz: 20 V/m
    IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF

  • Hazardous Locations

    Class I Division 2
    ATEX
    IECEx

  • Maritime

    DNV
    LR
    ABS
    NK

  • Railway

    EN 50121-4

  • Traffic Control

    NEMA TS2

  • Vibration

    IEC 60068-2-6

  • Shock

    IEC 60068-2-27

  • Freefall

    IEC 60068-2-32

  • Time

    2,174,016 hrs

  • Standards

    Telcordia (Bellcore), GB

Support Documents

Name Type Version Release Date
Datasheet for EDS-2010-ML Series
965.1 KB
Datasheet v2.0 Jul 10, 2023 Jul 10, 2023
QIG for EDS-2010/2018-ML Series
2.4 MB
QIG v1.5 Jan 10, 2023 Jan 10, 2023
2D CAD for EDS-2010-ML Series
751.3 KB
2D CAD Sep 11, 2019 Sep 11, 2019
Tech Note: Recommended Procedure for STP Cable Grounding on Moxa's Industrial Ethernet Switches
558.3 KB
Tech Note v1.0 Nov 16, 2016 Nov 16, 2016

Available Models (2)

Show Images
moxa-eds-2010-ml-2gtxsfp-image.jpg | MoxaEDS-2010-ML-2GTXSFPmoxa-eds-2010-ml-2gtxsfp-t-image.jpg | MoxaEDS-2010-ML-2GTXSFP-T
10/100BaseT(X) Ports (RJ45 connector)88
Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)22
Operating Temp.-10 to 60°C-40 to 75°C
Add to QuoteView BagAdd to QuoteView Bag

Gear Up Your Edge Network for Expanding Connectivity

The feature-rich EDS-2000 Series unmanaged switches can help save time, space, and cost for your edge network expansion in industrial applications.

Learn More

product image

Buy online from distributors

Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback