As of June 15, 2022, this site no longer supports Internet Explorer. Please use another browser for the best experience on our site.
MOXA

EN 50155 Routers

The routers in the TN Series are designed for rolling stock backbone networks and include high-performance M12 routers with four bypass relay backbone ports. They support NAT and routing functionality to facilitate the deployment of cross-network applications.

TN-4104-4TXBP-WV-CT-T
TN-4100 Series

TN-4104-4TXBP-WV-CT-T

Ethernet Interface
  • 100BaseT(X) Ports (M12 D-coded 4-pin female connector with bypass relay)

    • 4
  • Standards

    • IEEE 802.3u for 100BaseT(X)
LED Interface
  • LED Indicators

    • PWR, Ethernet ports, MDI/MDIX
Power Parameters
  • Input Current

    • 0.25 A @ 24 VDC
  • Input Voltage

    • 24/36/48/72/96/110 VDC
  • No. of Power Inputs

    • 2
  • Operating Voltage

    • 16.8 to 137.5 VDC
  • Power Connector

    • M12 K-coded 5-pin male connector
  • Overload Current Protection

    • Supported
  • Reverse Polarity Protection

    • Supported
Physical Characteristics
  • Housing

    • Metal
  • IP Rating

    • IP40
  • Dimensions

    • 115 x 159.8 x 70 mm (4.53 x 6.29 x 2.76 in)
  • Weight

    • 792 g (1.75 lb)
  • Installation

    • Wall mounting
  • Protection

    • PCB conformal coating
Environmental Limits
  • Operating Temperature

    • -40 to 70°C (-40 to 158°F)
  • Storage Temperature (package included)

    • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 3000 m
Standards and Certifications
  • EMC

    • EN 55032/35
  • EMI

    • CISPR 32, FCC Part 15B Class A
  • EMS

    • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
      IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF
  • Radio Frequency

    • FCC
  • Environmental Testing

    • IEC 60068-2-1, EN 50155
      IEC 60068-2-14, EN 50155
      IEC 60068-2-2, EN 50155
      IEC 60068-2-30, EN 50155
      IEC 60068-2-78
  • Railway

    • EN 50121-4
      EN 50155
      IEC 60571
  • Railway Fire Protection

    • EN 45545-2
  • Safety

    • IEC 62368-1
      UL 62368-1
      EN 62368-1
  • Salt Spray Test

    • EN 50155
  • Shock

    • IEC 60068-2-27, IEC 61373, EN 50155
  • Vibration

    • IEC 60068-2-64, IEC 61373, EN 50155
  • Package Vibration Test

    • ISTA 1A
  • Package Drop Test

    • ISTA 1A
Declaration
  • Green Product

    • RoHS, CRoHS, WEEE
MTBF
  • Time

    • 3,270,455 hrs
  • Standards

    • Telcordia SR332 Issue 4
Warranty
Added To Bag
You have some items waiting in your bag; click here to finish your quote!
Feedback